Application form Electrical Energy MeterEmail contact person * Name contact person * Name Applicant (=manufacturer) * Address applicant *Street AddressApt, Suite, Bldg. (optional)StadStaat / provincie / regioPostcodeAfghanistanAlbaniaAlgeriaAndorraAngolaAntigua and BarbudaArgentinaArmeniaAustraliaAustriaAzerbaijanBahamasBahrainBangladeshBarbadosBelarusBelgiumBelizeBeninBhutanBoliviaBosnia and HerzegovinaBotswanaBrazilBruneiBulgariaBurkina FasoBurundiCambodiaCameroonCanadaCape VerdeCentral African RepublicChadChileChinaColombiComorosCongo (Brazzaville)CongoCosta RicaCote d\'IvoireCroatiaCubaCyprusCzech RepublicDenmarkDjiboutiDominicaDominican RepublicEast Timor (Timor Timur)EcuadorEgyptEl SalvadorEquatorial GuineaEritreaEstoniaEthiopiaFijiFinlandFranceGabonGambia, TheGeorgiaGermanyGhanaGreeceGrenadaGuatemalaGuineaGuinea-BissauGuyanaHaitiHondurasHungaryIcelandIndiaIndonesiaIranIraqIrelandIsraelItalyJamaicaJapanJordanKazakhstanKenyaKiribatiKorea, NorthKorea, SouthKuwaitKyrgyzstanLaosLatviaLebanonLesothoLiberiaLibyaLiechtensteinLithuaniaLuxembourgMacedoniaMadagascarMalawiMalaysiaMaldivesMaliMaltaMarshall IslandsMauritaniaMauritiusMexicoMicronesiaMoldovaMonacoMongoliaMontenegroMoroccoMozambiqueMyanmarNamibiaNauruNepaNetherlandsNew ZealandNicaraguaNigerNigeriaNorwayOmanPakistanPalauPanamaPapua New GuineaParaguayPeruPhilippinesPolandPortugalQatarRomaniaRussiaRwandaSaint Kitts and NevisSaint LuciaSaint VincentSamoaSan MarinoSao Tome and PrincipeSaudi ArabiaSenegalSerbiaSeychellesSierra LeoneSingaporeSlovakiaSloveniaSolomon IslandsSomaliaSouth AfricaSpainSri LankaSudanSurinameSwazilandSwedenSwitzerlandSyriaTaiwanTajikistanTanzaniaThailandTogoTongaTrinidad and TobagoTunisiaTurkeyTurkmenistanTuvaluUgandaUkraineUnited Arab EmiratesUnited KingdomUnited States of AmericaUruguayUzbekistanVanuatuVatican CityVenezuelaVietnamYemenZambiaZimbabweLand Does the production location differ from the information above? *YesNo Production locationName producer (=factory) Address producer Street AddressApt, Suite, Bldg. (optional)StadStaat / provincie / regioPostcodeAfghanistanAlbaniaAlgeriaAndorraAngolaAntigua and BarbudaArgentinaArmeniaAustraliaAustriaAzerbaijanBahamasBahrainBangladeshBarbadosBelarusBelgiumBelizeBeninBhutanBoliviaBosnia and HerzegovinaBotswanaBrazilBruneiBulgariaBurkina FasoBurundiCambodiaCameroonCanadaCape VerdeCentral African RepublicChadChileChinaColombiComorosCongo (Brazzaville)CongoCosta RicaCote d\'IvoireCroatiaCubaCyprusCzech RepublicDenmarkDjiboutiDominicaDominican RepublicEast Timor (Timor Timur)EcuadorEgyptEl SalvadorEquatorial GuineaEritreaEstoniaEthiopiaFijiFinlandFranceGabonGambia, TheGeorgiaGermanyGhanaGreeceGrenadaGuatemalaGuineaGuinea-BissauGuyanaHaitiHondurasHungaryIcelandIndiaIndonesiaIranIraqIrelandIsraelItalyJamaicaJapanJordanKazakhstanKenyaKiribatiKorea, NorthKorea, SouthKuwaitKyrgyzstanLaosLatviaLebanonLesothoLiberiaLibyaLiechtensteinLithuaniaLuxembourgMacedoniaMadagascarMalawiMalaysiaMaldivesMaliMaltaMarshall IslandsMauritaniaMauritiusMexicoMicronesiaMoldovaMonacoMongoliaMontenegroMoroccoMozambiqueMyanmarNamibiaNauruNepaNetherlandsNew ZealandNicaraguaNigerNigeriaNorwayOmanPakistanPalauPanamaPapua New GuineaParaguayPeruPhilippinesPolandPortugalQatarRomaniaRussiaRwandaSaint Kitts and NevisSaint LuciaSaint VincentSamoaSan MarinoSao Tome and PrincipeSaudi ArabiaSenegalSerbiaSeychellesSierra LeoneSingaporeSlovakiaSloveniaSolomon IslandsSomaliaSouth AfricaSpainSri LankaSudanSurinameSwazilandSwedenSwitzerlandSyriaTaiwanTajikistanTanzaniaThailandTogoTongaTrinidad and TobagoTunisiaTurkeyTurkmenistanTuvaluUgandaUkraineUnited Arab EmiratesUnited KingdomUnited States of AmericaUruguayUzbekistanVanuatuVatican CityVenezuelaVietnamYemenZambiaZimbabweLand Product specificationType designation model/type name Meter type *StaticElectro-mechanical Network application *1p/2w3p/3w3p/3w ARON3p/4w Other Connection type *direct connectedCTCT/VT Reference voltage (include range if applicable) [V] * Minimum current [A] * Reference current [A] * Maximum current [A] * Reference frequency *50 Hz60 Hz Measurement capabilities *active importactive exportreactive importreactive export Test output *Visible LEDIR LEDSO Meter constant [imp/kWh] * Accuracy class - Active energy *IEC 2IEC 1IEC 0,5SIEC 0,2SMID AMID BMID C Accuracy class - Reactive energy *321(S)0,5S Operating temperature range *...˚C to ...˚C Environmental application *Indoor (IP51)Indoor (IP53)Indoor (IP54)Outdoor (IP54) IP 5x (dust) *without suctionwith suction Supply Control Switch (SCS) *also called breakerYesNo Load Control Switch (LCS/ACS) *relay to switch external loadsYesNo Communication interfaces OpticalMBUSPLCGPRSRS-232RS-485ZigbeeOther Additional information: E.g. special features, hard/software differences in case of multiple types) Sample requirementsSamples must be able to display all tariffs at 0,01 kWh/kVar resolution, time, date and checksum *Yes The Supply Control Switch (if applicable) should be closed at all times (e.g. no switch off at predefined current) *Yes The test output must be available for active and (if applicable) reactive energy. If different samples for different measurement capabilities are needed, this should be communicated upfront. *Yes Main servicesType test for Measuring Instruments Directive (MID) 2014/32/EU, Annex B in accordance with - EN 50470-1 in conjunction with EN 50470-2 or -3 as applicable - WELMEC 7.2 (type P (embedded software) Extension I3 (instrument specific requirements) and L (longterm storage) - Immunity investigation of electromagnetic disturbances in the frequency range 2-150 kHzYes Notes: 1. IEC 62052-11 and IEC 62053-11, -21, -22 as applicable are covered automatically in these tests 2. Welmec 7.2 is not applicable for Electro-mechanical meters Upper temperature Please specify+40 ˚C+55 ˚C+70 ˚C Lower temperature Please specify-10 ˚C-25 ˚C-40 ˚C Additional Welmex 7.2 Extensions S (software seperation)D (software download) Certificate of Conformity Yes IEC 62052-11 in conjunction with IEC 62053-11, -21 and/or -22 as applicable for active energy type tests Yes Additional test services IEC 62053-23 Reactive energy (class 2/3)IEC 62053-24 Reactive energy (class 05S,1S or 1)IEC 62055-31 Pre-payment metersIEC 62052-31 Safety testsIEC 62059-32-1 Durability testIEC 62059-31-1 Accelerated reliability testAccuracy test with one phase export and other phases importSP1618 Impulse voltage test at 12 kV (for Scandinavian market)Welmec 11.2 Load profilesOIML R 46 Active Electrical Energy MetersExtended Radio Frequency Immunity test up to 6 GHzIEC 62586-2 IEC 61000-4-30 Power Quality AnalyzersIEC 61557-1&12 Power Monitoring DevicesM6-1 Extra requirements for AustraliaMESS EV National German approval for reactive energyIEC 62052-21 IEC 62054-21 Time switchIEC 62052-21 IEC 62054-11 Ripple control receiverIEC 62055-31 Circuit breaker Annex C UC2IEC 62055-31 Circuit breaker Annex C UC3IEC 62055-31 Circuit breaker Annex C UC4IEC 60999-1 Terminal testsEN 50065-1 Power Line Communication (PLC) A BandEN 50065-1 Power Line Communication (PLC) C BandEN 300 220-2 EN 301 489-3 HF moduleEN 30148917 EN 3014891 EN 300 328 Zigbee communication2014/53/EU Conformity with RED (Radio Equipment Directive) Other / special requests: System Certification ServicesIf you want to put meters on the market in the European Union, you also need to able to perform a conformity assessment according to module D, F or H1 (see MID 2014/32/EC for an explanation). NMi also provides this service. For optimal preparation of the audit it is adviced to perform a training and have a pre-audit first. Training YesNo Pre-audit YesNo Audit YesNo Market informationWhen are your samples available? Do you have a specific deadline? What are your targeted markets?